(可调流量平衡阀)自力式控制阀

简要描述:RETZ (可调流量平衡阀)进口自力式控制阀用于需要进行流量控制的水系统中,尤其适用于供热、空调等非腐蚀性液体介质的流量控制。运行前一次性调节,即可使系统流量自动恒定在要求的设定值

  • 品牌:RETZ
  • 工况条件:调节
  • 温度/压力:P-T:16bar-120℃
  • 更新时间:2022/08/17
产品详情 在线咨询

技术参数 Technical paramete自力式可调流量控制阀(平衡阀)2.jpg

(可调流量平衡阀)进口自力式控制阀由自动调节阀瓣和手动调节阀瓣两部分组成。当系统流体工作压差超过300KPa时,为防止产生噪音,应采取措施将多余的压差消耗掉 RETZ self operated adjustable flow control valve (balance valve) is composed of two parts: automatic regulating valve disc and manual regulating valve disc. When the working pressure difference of system fluid exceeds 300kPa, measures shall be taken to consume the excess pressure difference to prevent noise

自力式可调流量控制阀(平衡阀)结构图.jpg

平衡阀不具备关断功能,根据需要应另设关断阀门。系统流体的工作压力为P1,手动调节阀瓣的前后压力分别为P2、P3。当手动调节阀瓣调到某一位置时,即人为确定了“设定流量”,以及相对应的固定(P2 -P3)值。当系统流量增大时,(P2-P3)的实际值超过了允许的给定值,此时自动调节阀瓣自动关小,直至流量重新维持到设定流量,反之亦然  RETZ balance valve does not have the shut-off function, and another shut-off valve shall be set as required. The working pressure of the system fluid is P1, and the front and rear pressures of the manual regulating valve disc are P2 and P3 respectively. When the manual regulating valve flap is adjusted to a certain position, the "set flow" and the corresponding fixed (P2 - P3) value are determined manually. When the system flow increases, the actual value of (P2-P3) exceeds the allowable given value, at this time, the automatic regulating valve disc automatically closes until the flow is maintained to the set flow again, and vice versa

工作原理简图.jpg

尺寸:F2"-20"  Size: F2 "- 20"

工作温度:0~90℃  Working temperature: 0 ~ 90 ℃进口自力式可调流量控制阀(平衡阀).jpg

承压等级:PN16  Pressure bearing grade: PN16 

控制精度∶  ±8%  Control accuracy: ± 8%

压差范围∶20-300KPa  Pressure difference range: 20-300kpa

工作介质∶冷、热水 Working medium: cold and hot water

连接方式∶法兰 Connection method: flange

阀体材质∶球墨铸铁  Valve body material: ductile iron

密封材质∶EPDM  Sealing material: EPDM


(可调流量平衡阀)进口自力式控制阀 性能特点∶ Performance characteristics

1、能使系统流量自动平衡在要求的设定值 The system flow can be automatically balanced at the required set value

2、能自动消除水系统中因各种因素引起的水力失调现象,保持用户所需流量,克服“冷热不均”,提高供热,空调的室温合格率  retz can automatically eliminate the hydraulic imbalance caused by various factors in the water system, maintain the flow required by users, overcome the "uneven cold and heat", and improve the room temperature qualification rate of heating and air conditioning

3、能有效地克服“大流量,小温度”的不良运行方式,提高系统能效  It can effectively overcome the bad operation mode of "large flow and small temperature" and improve the energy efficiency of the system