动态压差平衡阀

简要描述:RETZ进口动态压差平衡阀外在高压端测压头带有锁闭阀,低压腔体导压孔内置,避免了现场安装的磕碰。广泛应用于恒定空调或供热系统中控制阀、末端设备或管网之路供水之间的压差,避免管网压差变化对其动态干扰,实现动态水力平衡

  • 品牌:RETZ
  • 工况条件:开/关+手动调节
  • 温度/压力:P-T:16bar-120℃
  • 更新时间:2022/08/17
产品详情 在线咨询

技术参数 Technical paramete

进口动态压差平衡阀采用平衡膜片和弹簧均为内置设计,自动恒定压差的的平衡阀,通过手动旋钮即可设定目标压差值,使用内六角扳手旋转可实现手动关闭功能 RETZ The imported dynamic differential pressure balance valve adopts the built-in design of the balance diaphragm and spring. For the balance valve with automatic constant differential pressure, the target differential pressure can be set through the manual knob, and the function of manual closing can be realized by rotating the hexagonal wrench进口动态压差平衡阀2.jpg

尺寸:F2"-8"  Size: F2 "- 8"

工作温度:-10~120℃  Working temperature: -10 ~ 120 ℃

承压等级:PN16  Pressure bearing grade: PN16 

控制精度∶  ±8%  Control accuracy: ± 8%

压差设定范围∶20~80KPa或40~160KPa Pressure difference setting range: 20 ~ 80kPa or 40 ~ 160kpa

工作介质∶冷热水、乙/丙二醇溶液 Working medium: cold and hot water, ethylene / propylene glycol solution

连接方式∶法兰 Connection method: flange


进口动态压差平衡阀性能特点∶ Performance characteristics

手动关闭功能,用通用内六角扳手旋转即可实现RETZ Manual closing function can be realized by rotating with a universal Allen wrench

自力式压差控制,不需要外部动力源,恒定被控压差  Self operated differential pressure control, without external power source, constant controlled differential pressure

可现场设定压差值,可控压差范围广  The pressure difference can be set on site, and the controllable pressure difference range is wide

手轮带有压差设定指示,具有关断功能  The handwheel is provided with a pressure difference setting indication and a shut-off function

外置高压端侧压头,该测压头带有锁闭阀 External high-pressure side pressure head with locking valve

通过手动轮设定目标压差值,操作更加简便直观 Set the target pressure difference through the manual wheel, and the operation is more simple and intuitive


零部件材质 Component material

进口动态压差平衡阀结构图.jpg

①阀体:球墨铸铁QT450-10   Valve body: ductile iron QT450-10

②阀座:不锈钢  Valve seat: stainless steel

③阀芯:不锈钢304  Valve core: stainless steel 304

④阀杆∶不锈钢304  Valve stem: stainless steel 304

⑤弹簧:不锈钢304 Spring: stainless steel 304

⑥膜片:EPDM  Diaphragm: EPDM

⑦密封:氟橡胶 Seal: fluororubber

⑧手轮压:铸铝 Handwheel press: cast aluminum

⑨测量嘴:不锈钢 Measuring nozzle: stainless steel


工作范围

进口动态压差平衡阀工作范围.jpg

A.KVmin   B.KVnom   C.KVmax   D.工作范围△P∶±25%


安装说明 Installation instructions

动态压差平衡阀可以单独使用,亦可与静态平衡阀配合使用。水流方向需与阀体箭头方向符合一致。安装之前应当冲洗管路,并建议在前端安装过滤器。毛细管应连接在供水管路的上方或水平处,但不可位于管路下方,以防被灰尘微粒堵塞,水系统打压测试之前,必须把毛细信号管安装连接好并且旋转阻断阀。否则压力过大会导致压差调节器的损坏 RETZ internal thread dynamic differential pressure balancing valve can be used alone or in combination with static balancing valve. The water flow direction shall be consistent with the arrow direction of the valve body. The pipeline should be flushed before installation, and it is recommended to install a filter at the front end. The capillary shall be connected above or at the level of the water supply pipeline, but not below the pipeline to prevent it from being blocked by dust particles. Before the pressure test of the water system, the capillary signal pipe must be installed and connected and the blocking valve must be rotated. Otherwise, excessive pressure will cause damage to the differential pressure regulator.

进口动态压差平衡阀安装说明.jpg

动态压差平衡阀始终安装于回水管上,当与静态平衡阀配合使用时,如下图所示静态平衡阀安装与供水管  RETZ dynamic differential pressure balance valve is always installed on the return pipe. When used with the static balance valve, the static balance valve is installed on the water supply pipe as shown in the following figure

①-动态压差平衡阀 Dynamic differential pressure balancing valve

②-静态平衡阀 Static balancing valve

③-电动调节阀 Electric control valve


产品中心
相关产品